RuncoN CT Machine Electrical Panel is the main electrical control and distribution unit for a Computed Tomography (CT) scanner system. It manages and protects the electrical power supply to all parts of the CT system — including the gantry, X-ray tube, high-voltage generator, patient table, operator console, and cooling system — ensuring safe, stable, and uninterrupted operation.
Our panels are custom-engineered to meet the exact power and wiring specifications of the installed CT system, complying with IEC 60601 and NFPA 99 medical electrical standards. With dedicated power feeds, built-in surge protection, isolation transformers, and emergency stop circuits, every RuncoN CT panel is built to protect both the equipment and the patient.
| ♦ Minimum Order Quantity: | 1 Piece |
| ♦ Application: | CT Scanner / Computed Tomography Systems |
| ♦ Input Supply: | 400 V ±10%, 3-Phase, 50/60 Hz |
| ♦ Power Rating: | 60–100 kVA (as per CT model) |
| ♦ Phase: | Three Phase, 4-Wire |
| ♦ Isolation Transformer: | Included (Galvanic Isolation) |
| ♦ Protection: | MCB, SPD, Emergency Stop, Ground Fault |
| ♦ UPS Provision: | Console / Computer Systems on UPS |
| ♦ IP Rating: | IP54 |
| ♦ Body Material: | CRCA / Mild Steel with Powder Coating |
| ♦ Compliance: | IEC 60601, NFPA 99, Local Electrical Codes |
| ♦ Dimension: | Customized to Site Requirements |
| ♦ Brand: | RuncoN — Maurya Enterprises |
| ♦ Country of Origin: | Made in India |
The RuncoN CT Electrical Panel serves as the nerve centre for all power management and control functions of the CT scanner — delivering clean, protected, and distributed power to every subsystem while maintaining continuous safety monitoring.
Every RuncoN CT Electrical Panel is assembled with precision-grade, medical-standard components — each selected for long-term reliability, compatibility with CT OEM specifications, and ease of service access.
CT scanners require a dedicated, isolated three-phase power supply with tightly regulated voltage and frequency. The exact specification is provided by the CT OEM and must be followed precisely during installation.
| Parameter | Specification | Notes |
|---|---|---|
| Input Supply | 400 V ±10%, 3-Phase | Dedicated isolated circuit |
| Frequency | 50 / 60 Hz | Depends on local grid |
| Power Rating | 60–100 kVA | Varies by CT model |
| Dedicated Line | Isolated ground required | Separate from building ground |
| UPS / Backup | Computer / console on UPS | For uninterrupted operation |
+-----------------------------------------------------+ | MAIN CIRCUIT BREAKER | | --> Surge Protection Device (SPD) | | --> Isolation Transformer | | --> Power Contactors & Relays | | --> Circuit Breaker Distribution Bank | | - Gantry Drive System | | - X-Ray High Voltage Generator | | - Patient Table Drive | | - Console / Computer (UPS) | | - Cooling System / Fan | | - Lighting / HVAC Control | | --> Grounding & Bonding System | | --> Emergency Stop Circuit | +-----------------------------------------------------+